Input: pink crank rotating regularly.
Blue crank is identical to the pink one and rotates with the same velocity and in opposite direction.
Output: yellow Geneva disk oscillating with dwells at its stroke ends. Oscillating angle: 90 deg.
The sectors of the two cranks help keeping the output shaft immobile during its dwells.